Cavitation can damage pump components and degrade performance. Suction-system evaluation is an essential part of pump selection, especially at elevated temperature, high flow and low inlet pressure.

1. What is cavitation?

Cavitation occurs when local liquid pressure falls low enough for vapor bubbles to form and then collapse in higher-pressure regions. Noise, vibration, loss of performance and material damage can result. Similar symptoms can have other causes, so diagnosis should not rely on noise alone.

2. NPSH available versus required

NPSH available (NPSHa) characterizes suction conditions in the installed system. NPSH required (NPSHr) is a manufacturer-provided performance metric determined under defined test conditions. The available margin should follow the applicable design and manufacturer guidance; simply having NPSHa slightly above NPSHr may not provide sufficient reliability.

Simplified open-tank NPSHa ≈ atmospheric head + liquid surface elevation above pump − suction friction head − vapor pressure head

All terms must use the same liquid density and consistent reference elevation. For pressurized or vacuum vessels, include actual vessel absolute pressure. Temperature strongly affects vapor pressure.

3. Common ways to improve suction conditions

  • Reduce suction-line friction: reconsider pipe diameter, length, fittings and strainers.
  • Increase static liquid level above the pump when practical.
  • Consider fluid temperature and vapor pressure.
  • Review operating speed or the pump model where appropriate.
  • Inspect for blocked strainers, air ingress, or operating conditions outside the specified envelope.

4. Questions for a pump supplier

Request the NPSHr curve at the intended operating speed, the basis for published ratings, recommended NPSH margin, suction-inlet requirements, liquid-property correction guidance, and the acceptable operating range.

Do not use this simplified explanation as the sole basis for a safety-critical pump installation.