HydroTechnica
Technical guide

Pressure versus head: how to convert correctly

Learn the difference between pressure and fluid head, including conversions for water and changes in density.

Engineering fundamentals

Head represents energy per unit weight of fluid, while pressure is force per unit area. They are related through fluid density; that is why a fixed pressure does not represent the same head for every liquid.

1. Pressure and hydrostatic head

h (m) = Δp (Pa) / [ρ (kg/m³) × g (m/s²)]

For a liquid with density near 1,000 kg/m³ and standard gravity, 1 bar of pressure difference corresponds to approximately 10.20 m of head. This approximation is often convenient for water near ordinary ambient conditions, but it is not a constant for every fluid or temperature.

2. Common examples

Pressure differentialApproximate head for ρ = 1,000 kg/m³
50 kPa (0.5 bar)5.10 m
100 kPa (1 bar)10.20 m
250 kPa (2.5 bar)25.49 m

3. Use it in system design

Pump head is not merely the height of an outlet above a pump. A complete system assessment must consider endpoint pressure, elevations, velocity effects and friction losses. Density matters when translating pressure into head, and fluid viscosity affects losses and pump performance.

4. A frequent conversion error

It is incorrect to assume 1 bar always equals 10 m for oil, concentrated process chemicals or slurry. When density changes, the equivalent head changes. Verify the relevant operating temperature and fluid properties.

Try the water-pump power calculator using your liquid density.

Engineering note: This guide is informational, not a certified design, product approval, or professional engineering assessment. Verify all operating conditions and use relevant manufacturer data, local standards, and appropriate technical review before procurement or installation.

Last updated: 2026-11-22 · Published by HydroTechnica. Editorial approach.