Engineering fundamentals
Head represents energy per unit weight of fluid, while pressure is force per unit area. They are related through fluid density; that is why a fixed pressure does not represent the same head for every liquid.
1. Pressure and hydrostatic head
For a liquid with density near 1,000 kg/m³ and standard gravity, 1 bar of pressure difference corresponds to approximately 10.20 m of head. This approximation is often convenient for water near ordinary ambient conditions, but it is not a constant for every fluid or temperature.
2. Common examples
| Pressure differential | Approximate head for ρ = 1,000 kg/m³ |
|---|---|
| 50 kPa (0.5 bar) | 5.10 m |
| 100 kPa (1 bar) | 10.20 m |
| 250 kPa (2.5 bar) | 25.49 m |
3. Use it in system design
Pump head is not merely the height of an outlet above a pump. A complete system assessment must consider endpoint pressure, elevations, velocity effects and friction losses. Density matters when translating pressure into head, and fluid viscosity affects losses and pump performance.
4. A frequent conversion error
It is incorrect to assume 1 bar always equals 10 m for oil, concentrated process chemicals or slurry. When density changes, the equivalent head changes. Verify the relevant operating temperature and fluid properties.
Try the water-pump power calculator using your liquid density.
Last updated: 2026-11-22 · Published by HydroTechnica. Editorial approach.